Pressure Sensor Differential Amplifier

PRESSURE SENSOR DIFFERENTIAL AMPLIFIER

Fire Detection Unit Front

The differential amplifier will be housed in an aluminium enclosure. The differential amplifier has two input channels and each of these input channels can accept a 4..20mA signal coming from the pressure sensor. The output of the amplifier is the difference of the two input pressures (differential) and is provided as a 4..20mA signal. Both input and output signals are connected to the amplifier through 5 pin circular connectors of type KPSE06E14-5S and corresponding mating receptacle in the amplifier housing.

The Pressure sensor is made of piezoresistive element packaged in surface mount configuration and attached to a ceramic substrate, capable of an operating temperature (fluid temperature) of -40°C to +125°C. The sensing element associated with the amplifier and current converter, housed in a printed circuit board, will be embedded in a stainless steel housing. Packaged pressure sensor will work as a two wire sensor providing 4-20mA output corresponding to 0..4 bar pressure.

Fire Detection Unit Front

Key Features

Fire Detection Unit Front
  • 4-20mA output signal, interfaces with converter control.
  • Separate sensors mounted at the inlet and outlet of the heat exchanger.
  • Maximum differential pressure: 2 Bar. and Sensing range: 0-4 Bar.
  • Micro controller based amplifier, easy to calibrate.
  • Honeywell make sensors used.
  • IEC-60571 compliant.

How System Works

Pressure Sensor Working Diagram